Study on the Multi-Spectral True Temperature Pyrometer for Explosion Transient of Thermo-Baric Explosives

2016-07-12 12:43ZHANGFucaiSUNXiaogangXINGJian
光譜學(xué)與光譜分析 2016年5期
關(guān)鍵詞:溫壓瞬態(tài)傳感

ZHANG Fu-cai, SUN Xiao-gang*, XING Jian

1.Harbin Institute of Technology, Harbin 150001, China 2.Harbin Engineering University, Harbin 150001, China

Study on the Multi-Spectral True Temperature Pyrometer for Explosion Transient of Thermo-Baric Explosives

ZHANG Fu-cai1, SUN Xiao-gang1*, XING Jian2

1.Harbin Institute of Technology, Harbin 150001, China 2.Harbin Engineering University, Harbin 150001, China

The high temperature and destructive power, made it difficult to test the explosion temperature of thermo-baric explosive.To effectively assess heat damage effect of thermo-baric explosive, multi-spectral high temperature measurement system is applied to transient high temperature test of thermo-baric explosive.The emissivity and the true temperature of explosion flame are calculated by using the secondary measurement method.In the data acquisition system, the test instrument achieves data collection and transmission 500 meters away in combination with optical fiber sensing technology and under the precondition to guarantee the participants safety.The measurement results show that the designed measurement system has the advantages of simple operation, high safety and better application prospect.

Thermo-baric; Multi-spectral; True temperature; Optical fiber sensing technology

Introduction

Thermo-baric has the feature of high explosion temperature and great explosive energy.Therefore, it is difficult to test the explosion temperature.Traditional explosives mainly take metal fragments, thermal jet, etc.as the main killing and damaging means.Therefore, they are often used for damaging above-ground buildings, injuring or even killing above-ground personnel.However, thermo-baric can burn violently after detonation and release a lot of heat energy within short time of period, thereby utilizing radiant heat energy to generate killing and damaging force.Thermo-baric is mainly used to damage effective strength in caves, underground fortifications, bunkers and other enclosed spaces.Therefore, the temperature of thermo-baric is an important index to measure the explosive force and it is important in study energy release rule and thermal damage effect.Thermo-baric has become the hotspot in research and development of mixed explosives[1-2].Owe to short explosion time, violent change of temperature, safety and other factors in thermo-baric, it is difficult to measure the explosion flame temperature.In recent years, improvement of multi-spectral theory and development of detection technology have laid foundation for measuring the true temperature in an explosion flame temperature field and provided the possibility for the detection of true temperature in an explosion flame temperature field.Multi-spectral thermometer based on prismatic decomposition is applied widely thanks to its simple structure, low cost, flexible design, among others.Harbin Institute of Technology successfully measured the true temperature of solid rocket wake flame[3-4]with prism multi-spectral thermometer, which proved that through elaborate design and improvement, multi-spectral thermometer of prismatic decomposition type could be applied in a hostile environment.The paper solves the problem based on multi-spectral method, wireless transmission and other critical technologies, and successfully designs the true temperature measuring apparatus applicable to the explosion field of thermo-baric explosives.The test system is distributed into the explosion field.In this way, the researcher can monitor the operating mode of the system in long distance and complete collection and storage of temperature parameter in the field.Afterwards, the measured temperature information is processed and reproduced by a computer[5-7].

1 Measurement principle of multi-spectral temperature

It is assumed that the multi-spectral temperature measurement system has N spectral channels and it is brightness temperature information passing through these different channels, then the voltage valueViof the output signal from channelican be expressed as

(1)

(2)

Type (1) divided by type (2)

(3)

(4)

We select coefficient of emissivitya>0 and emissivity model of second temperature are as below

(5)

(6)

(7)

(8)

where

Theanalysisaboveshowsthatthereisarelationshipbetweenthemulti-spectralalgorithmsandemissivityandrealizecontinuouscalculationwithoutassumingtheiterativeinitialvalue.Byappropriatelyselectiterativecut-offconditionEr,itcanmeettherequirementofthemeasurementprecisionexcepttheiterationtimeisdifferent.

Fig.1 Schematic of measurement

2 Overall structure of multi-spectral thermometry system

Multi-spectral radiation thermometry system consists of multiple spectral channels in one instrument to simultaneously obtain the multi-spectral radiance measurement information of the target point to be measured, which is processed to obtain the true temperature and spectral emissivity of target.Having no special requirements on the target, the method is particularly applied to simultaneous measurement of true temperature and material emissivity of high temperature and very high temperature target.The measurement system comprises mainly optical system (optical sight, optical splitting system and photoelectric converter), data conditioning system, high speed data acquisition system, fiber remote transmission module, PC and other parts.The general structure diagram of the measurement system is shown in figure 1.

3 Calibration of measurement system

Calibration of measurement device is divided into wavelength function (PWF) calibration and brightness temperature calibration.By using wavelength calibration, we get the working wavelength of each channel of the instrument.The specific calibration results for operating wavelength of the instrument in various channels are shown in Table 1 and wavelength functions of some channels are shown in figure 2.

Table 1 Effective wavelengths of pyrometer (nm)

Fig.2 Part of PWF of Target 1

Calibration is carried out in Beijing Aerospace Hospital (professional thermal measurement calibration station specified by the department of space).The pyrometer and standard meter are respectively aligned with the window of the high temperature blackbody furnace.The output spectral region of the blackbody furnace contains the spectral range of the pyrometer.From 900 to 3 000 ℃, every hundredth temperature point is taken as a measuring point and each measurement point is sampled for 500 times.Afterwards, the average value is seen as the measurement value.The output temperature value of the standard meter is taken as the brightness temperature value of the temperature point and recorded in pair with the voltage measurement value.Owing to the wide measurement temperature range of instrument, the brightness temperature calibration contains medium low temperature zone (below 2 000 ℃) and high temperature zone (above 2 000 ℃).For medium low temperature zone, we adopt whole hundredth calibration method and for high temperature zone, we adopt one point calibration method[8-10].Some brightness temperature calibration results are shown in tables 2 and 3.

Table 2 Data of brightness temperature calibration of target 1 (Unit: V)

Table 3 Data of brightness temperature calibration of target 2 (Unit: V)

Fig.3 Variation curves of voltage channel 1 and channel 5 corresponds with the time

4 Experimental results

The explosion processes of thermo-baric explosive with different proportion are measured based on above multi-spectral thermometry system and a series of curves of voltage U changing with time t are obtained.Fig.3 is the changing curve between voltage and time of thermo-baric explosive in two channels therein.

From figure 3, we can see that thermo-baric explosive temperature has obvious transient and large damage area accompanied by a strong shock.In the time of 600 μs, thermo-baric explosive generates a large amount of toxic gas and smoke, which lead to local combustion hypoxia.Therefore, it is measured that the voltage of the output channel has certain fluctuation and repeated phenomenon at about 600 μs.

It can be observed from figure 4 that a temperature peak appears in dozens of microseconds after explosion of thermo-baric explosive.Afterwards, temperature has obvious descending trend.With the change of time, the 2nd temperature peak appears after explosion of the thermo-baric explosive mainly because of burning of fuel particles.After explosion, thermo-baric explosive absorbs a great deal of oxygen from the surrounding air, which leads to the secondary aerobic combustion.Finally, with the extension of time, temperature gradually declined; At this stage, due to the fireball volume expanding and large amounts of energy is released, the degree of damage to the surrounding environment is getting more and more serious.

Fig.4 Curves of temperature change with time

5 Conclusion

Through the study of multi-spectral theory, we have successfully developed the multi-spectral thermometer applicable to detecting true temperature of thermo-baric explosive.The instrument appraises destructive power and killing ability of thermo-baric explosive from temperature angle.Long distance wireless temperature test helps with the wiring difficulties and the great dangers in measurement of explosion temperature field are get rid of by means of the wireless sensing network technology.Therefore, the paper is a foundation for multi-spectral detection in the explosion temperature field of thermo-baric explosive in the future and thereby is of practical significance.

[1] LI Zhong-gen, ZHOU Guo-yi.Advanced Materials Research, 2011, 328(5): 327.

[2] LI Yun-hong, SUN Xiao-gang, WANG Yan-nian, et al.Infrared and Laser Engineering, 2010, 39(5): 801.

[3] LIU Ning, FENG Zhi-qiang, HUANG Bo-yong, et al.Chinese Journal of Explosives & Propellants, 2014, 37(5): 28.

[4] WANG Dai-hua, SONG Lin-li, ZHANG Zhi-jie.Chinese Journal of Sensors and Actuators, 2012, 25(4): 478.

[5] DU Lin, MA Ying-ying, ZHU Bo, et al.Acta Optica Sinica, 2014, 34(8): 0828001-1.

[6] YU Wei-xiong, DAI Jing-min, et al.Infrared and Laser Engineering, 2014, 43(5): 1390.

[7] SUN Xiao-gang, SUN Kun, DAI Jing-min.Spectroscopy and Spectral Analysis, 2012, 32(1): 273.

[8] SUN Kun, SUN Xiao-gang, YU Xiao-yang.Spectroscopy and Spectral Analysis, 2013, 33(6): 1723.

[9] WANG Jian, PEI Dong-xin, WANG Wei.Chinese Journal of Sensors and Actuators, 2013, 26(4): 516.

[10] WEN Shu-Sheng, HUANG Jiong, SHU Ting, et al.Journal of Software, 2014, 24(9): 2151.

[11] ZHOU Huai-chun, LUO Zi-xue, LOU Chun.Journal of Chinese Society of Power Engineering, 2010, 30(8): 593.

[12] FU Tai-ran, YANG Zang-jian, CHENG Xiao-fang.Proceedings of the CSEE, 2009, 29(2): 81.

*通訊聯(lián)系人

TK311

A

溫壓炸藥爆炸瞬態(tài)多光譜真溫高溫計(jì)的研究

張福才1,孫曉剛1*,邢 鍵2

1.哈爾濱工業(yè)大學(xué),黑龍江 哈爾濱 150001 2.哈爾濱工程大學(xué),黑龍江 哈爾濱 150001

溫壓炸藥爆炸溫度高且具有較強(qiáng)的破壞力,因而使其爆炸溫度測(cè)試較為困難。為有效評(píng)估溫壓炸藥的熱溫度毀傷效力,將多光譜溫度測(cè)量系統(tǒng)應(yīng)用到溫壓炸藥瞬態(tài)高溫測(cè)試中,利用二次測(cè)量法計(jì)算出爆炸火焰的發(fā)射率與真溫。在數(shù)據(jù)采集系統(tǒng)中結(jié)合光纖線傳感技術(shù),在確保參試人員的安全前提下,可在500 m外測(cè)試儀器狀態(tài)進(jìn)行數(shù)據(jù)采集,實(shí)現(xiàn)了測(cè)量數(shù)據(jù)信息的遠(yuǎn)距離傳遞。測(cè)試結(jié)果表明,所設(shè)計(jì)的測(cè)量系統(tǒng)工作穩(wěn)定、安全性高,具有良好的應(yīng)用前景。

溫壓炸藥; 多光譜; 真溫; 光纖傳感技術(shù)

2014-12-07,

2015-04-06)

Foundation item:Special Project for Development of Major National Scientific Instrument and Equipment (2013YQ470767), Natural Science Foundation of China (61405045), Project Funding of Science and Technology Department of Heilongjiang Province(12521487)

10.3964/j.issn.1000-0593(2016)05-1598-06

Received:2014-12-07; accepted:2015-04-06

Biography:ZHANG Fu-cai,(1978—),doctoral student of Harbin Institute of Technology e-mail: qingtengzfc@yeah.net *Corresponding author e-mail: 510132156@qq.com

猜你喜歡
溫壓瞬態(tài)傳感
《傳感技術(shù)學(xué)報(bào)》期刊征訂
新型無(wú)酶便攜式傳感平臺(tái) 兩秒內(nèi)測(cè)出果蔬農(nóng)藥殘留
復(fù)雜溫壓條件下循環(huán)載荷對(duì)水泥環(huán)密封完整性的影響實(shí)驗(yàn)研究
高壓感應(yīng)電動(dòng)機(jī)斷電重啟時(shí)的瞬態(tài)仿真
IPv6與ZigBee無(wú)線傳感網(wǎng)互聯(lián)網(wǎng)關(guān)的研究
溫壓炸藥在無(wú)氧環(huán)境下的能量輸出研究
溫壓炸藥在野外近地空爆中的沖擊波規(guī)律
十億像素瞬態(tài)成像系統(tǒng)實(shí)時(shí)圖像拼接
基于瞬態(tài)流場(chǎng)計(jì)算的滑動(dòng)軸承靜平衡位置求解
DC/DC變換器中的瞬態(tài)特性分析
永登县| 芮城县| 无锡市| 茌平县| 阿鲁科尔沁旗| 东安县| 徐州市| 浦县| 闵行区| 正宁县| 瓦房店市| 札达县| 河北区| 石首市| 观塘区| 五台县| 呼伦贝尔市| 兴宁市| 淮阳县| 台山市| 宁国市| 枣庄市| 常山县| 中宁县| 获嘉县| 栾城县| 陆川县| 滕州市| 伽师县| 宜昌市| 灵寿县| 民权县| 景泰县| 新乡市| 宝鸡市| 东至县| 潜江市| 华阴市| 神木县| 拜城县| 旅游|