欒松強(qiáng) 黃建新
摘要:如何發(fā)揮狀態(tài)監(jiān)測故障診斷技術(shù)在設(shè)備管理中的應(yīng)用,提升本單位設(shè)備管理水平,最終使企業(yè)由點檢定修檢修模式向點檢定修+狀態(tài)維修相結(jié)合模式科學(xué)發(fā)展。
關(guān)鍵詞:風(fēng)機(jī)、軸承特征頻率、軸承內(nèi)環(huán)、頻譜分析、測點
Analysis of State Monitoring on dedusting fan in coking
LUAN Songqiang ,HUANG Jianxin
( BAOSTELL GROUP XINJIANG BAYI IRON &STELL CO.LTD ,Toutunhe District, Urumuqi 830022, Xinjiang Autonomous Region,China)
Abstract:Advancement of device management by state monitoring fault diagnosis technology,Make our device management develop along Combined with Preventive Maintenance and Condition Based Maintenance lines.
Key words: fan; eigenfrequency of bearing; bearing inner race; spectral decomposition; measuring point
八鋼新區(qū)6米4×55孔復(fù)熱式頂裝焦?fàn)t一期篩焦除塵風(fēng)機(jī)
電機(jī)型號:YKK5604-610000V220KW991rpm
調(diào)速型液力偶和器型號:YOTCGP 875/10001000rpm
離心引風(fēng)機(jī)型號:D/250-1.24/0.89960rpm
該設(shè)備在2010年11月2日發(fā)現(xiàn)離心引風(fēng)機(jī)軸承座負(fù)荷端5號測點出現(xiàn)異常,風(fēng)機(jī)轉(zhuǎn)頻振動幅值開始呈上升趨勢,并伴隨出現(xiàn)一個120Hz的故障頻率,通過連續(xù)的狀態(tài)檢測,到24日振動幅值還呈上升趨勢,根據(jù)該設(shè)備歷史數(shù)據(jù)比較和ISO2372振動判定標(biāo)準(zhǔn),當(dāng)日向點檢人員發(fā)出停機(jī)檢修警告,設(shè)備方11月27日安排停機(jī)檢修,發(fā)現(xiàn)軸承內(nèi)環(huán)鎖緊螺母松動,隨即進(jìn)行了緊固處理,根據(jù)28日開機(jī)后狀態(tài)檢測分析,120Hz故障頻率也隨即消失,設(shè)備恢復(fù)正常狀態(tài),及時在設(shè)備故障萌芽狀態(tài)解決問題避免了設(shè)備故障的擴(kuò)大化。
軸承型號 內(nèi)環(huán)特征
頻率 外環(huán)特征
頻率 滾子特征
頻率 保持架特征
頻率 轉(zhuǎn)速
22232
調(diào)心滾子軸承 165Hz 120Hz 48Hz 6.65Hz 950
具體分析如下:
頻譜分析
(一)測點分布:
(二)振動幅值比較分析
測點 測量值 采集時間 測點 測量值 采集時間
風(fēng)機(jī)5A速度 2.1mm/s 2010-11-30 13:00:04 風(fēng)機(jī)6A速度 1.7mm/s 2010-11-30 13:01:28
3.9mm/s 2010-11-28 14:08:50 2.5mm/s 2010-11-28 14:10:19
8.7mm/s 2010-11-24 11:28:58 5.2mm/s 2010-11-24 11:30:51
7.5mm/s 2010-11-23 13:18:27 4.5mm/s 2010-11-23 13:20:22
5.7mm/s 2010-11-19 12:06:00 3.7mm/s 2010-11-19 11:58:51
6.6mm/s 2010-11-02 11:35:49 5.1mm/s 2010-11-02 11:37:27
4.0316mm/s 2010-10-26 12:10:17 3.1423mm/s 2010-10-26 12:12:27
3.6166mm/s 2010-10-12 12:12:56 2.6976mm/s 2010-10-12 12:15:04
3.667mm/s 2010-09-26 12:27:41 2.6957mm/s 2010-09-26 12:29:32
5.1mm/s 2010-09-20 12:09:27 3.4291mm/s 2010-09-20 12:11:46
風(fēng)機(jī)5H速度 2.5mm/s 2010-11-30 13:00:18 風(fēng)機(jī)6H速度 1.3mm/s 2010-11-30 13:01:49
2.8mm/s 2010-11-28 14:09:11 1.2mm/s 2010-11-28 14:10:39
2.2mm/s 2010-11-24 11:29:25 0.7mm/s 2010-11-24 11:31:13
2.3116mm/s 2010-11-23 13:18:51 0.7236mm/s 2010-11-23 13:20:48
2.1344mm/s 2010-11-19 12:06:26 0.8202mm/s 2010-11-19 11:59:19
2.4mm/s 2010-11-02 11:36:12 0.7mm/s 2010-11-02 11:37:49
1.5119mm/s 2010-10-26 12:10:57 0.504mm/s 2010-10-26 12:12:58
2.2727mm/s 2010-10-12 12:13:30 0.5632mm/s 2010-10-12 12:15:29
2.0813mm/s 2010-09-26 12:28:14 0.773mm/s 2010-09-26 12:29:59
2.666mm/s 2010-09-20 12:10:26 0.6739mm/s 2010-09-20 12:12:13
風(fēng)機(jī)5V速度 1mm/s 2010-11-30 13:00:40 風(fēng)機(jī)6V速度 0.4mm/s 2010-11-30 13:02:10
1.1mm/s 2010-11-28 14:09:33 0.4mm/s 2010-11-28 14:11:00
1.6mm/s 2010-11-24 11:29:49 0.3mm/s 2010-11-24 11:31:34
1.0854mm/s 2010-11-23 13:19:18 0.3015mm/s 2010-11-23 13:21:15
1.1759mm/s 2010-11-19 12:06:52 0.3656mm/s 2010-11-19 11:59:45
1.4mm/s 2010-11-02 11:36:36 0.3mm/s 2010-11-02 11:38:11
1.1561mm/s 2010-10-26 12:11:25 0.4348mm/s 2010-10-26 12:13:26
1.0079mm/s 2010-10-12 12:13:59 0.3557mm/s 2010-10-12 12:15:56
1.2686mm/s 2010-09-26 12:28:41 0.3271mm/s 2010-09-26 12:30:26
1.3181mm/s 2010-09-20 12:10:54 0.337mm/s 2010-09-20 12:12:41
可以看到,風(fēng)機(jī)5#、6#軸向測點在24日達(dá)到最高點,軸向測點振動幅值分別為9.0mm/s和5.2mm/s,根據(jù)ISO2372振動判定標(biāo)準(zhǔn)需要停機(jī)檢修了,及時下發(fā)了停機(jī)檢修報告,軸承鎖緊螺母處理后振動幅值趨于正常;
(三)頻譜圖比較分析
煉鐵分公司新區(qū)焦化27.一期篩焦除塵風(fēng)機(jī)5A風(fēng)機(jī)負(fù)載端5A速度采樣時間:2010-11-24 11:28:58,測量值:8.7mm/s
煉鐵分公司新區(qū)焦化27.一期篩焦除塵風(fēng)機(jī)5A風(fēng)機(jī)負(fù)載端5A速度采樣時間:2010-11-24 11:28:58,測量值:8.7mm/s
煉鐵分公司新區(qū)焦化27.一期篩焦除塵風(fēng)機(jī)5A風(fēng)機(jī)負(fù)載端5A速度采樣時間:2010-11-24 11:28:58,測量值:8.7mm/s
煉鐵分公司新區(qū)焦化27.一期篩焦除塵風(fēng)機(jī)5A風(fēng)機(jī)負(fù)載端5A速度
煉鐵分公司新區(qū)焦化27.一期篩焦除塵風(fēng)機(jī)6A風(fēng)機(jī)自由端6A速度
總結(jié)
本次檢修只是軸承內(nèi)環(huán)鎖緊螺母緊固處理后,風(fēng)機(jī)5#、6#兩測點軸向振動幅值顯著下降,軸承內(nèi)環(huán)特征頻率也有所下降;前期考慮到只在軸向頻譜圖中看到軸承內(nèi)環(huán)頻率,而在水平和垂直頻譜圖中不明顯,所以只是建議對軸承進(jìn)行檢查,本次是在故障頻率出現(xiàn)一定時間,根據(jù)劣化趨勢而確定出具停機(jī)檢修報告的,根據(jù)檢查結(jié)果,分析是準(zhǔn)確及時的。通過有計劃合理安排檢修時間、資源進(jìn)行了本次檢修;也充分體現(xiàn)了狀態(tài)監(jiān)測參與設(shè)備點檢、維護(hù)的作用及價值。
這是一次典型的精密點檢+狀態(tài)維修相結(jié)合的科學(xué)維修修方式。
參考文獻(xiàn):韓捷.旋轉(zhuǎn)設(shè)備故障機(jī)理及診斷技術(shù)(M).機(jī)械工業(yè)出版社,1997
注:文章內(nèi)所有公式及圖表請以PDF形式查看。