張舜
[摘? ? 要]電氣設(shè)備是電廠生產(chǎn)運(yùn)營中的重要組成部分,對電廠經(jīng)營效益和安全管理工作目標(biāo)的實(shí)現(xiàn)有著緊密的關(guān)系。通過對電廠電氣設(shè)備常見故障進(jìn)行分析,采取科學(xué)的設(shè)備故障處理措施是十分必要的。本文就這一議題進(jìn)行了探討,并對電氣設(shè)備維護(hù)技術(shù)和檢修技術(shù)的要點(diǎn)進(jìn)行了論述,供相關(guān)人士參考。
[關(guān)鍵詞]電氣設(shè)備故障處理;故障原因;技術(shù)維護(hù);檢修措施
[中圖分類號(hào)]TM621 [文獻(xiàn)標(biāo)志碼]A [文章編號(hào)]2095–6487(2020)09–00–03
[Abstract]Electrical equipment is an important part of power plant production and operation, which has a close relationship with the realization of power plant operation efficiency and safety management objectives. By analyzing the common faults of electrical equipment in power plant, it is very necessary to take scientific measures to deal with equipment faults. This paper discusses this issue, and discusses the key points of electrical equipment maintenance technology and overhaul technology, for reference.
[Keywords]electrical equipment fault treatment; fault reason; technical maintenance; overhaul measures
只有確保電氣設(shè)備始終處于安全穩(wěn)定的運(yùn)行狀態(tài),才能使電廠生產(chǎn)運(yùn)營的目標(biāo)順利實(shí)現(xiàn)。近年來,電力企業(yè)面臨越來越激烈的市場競爭環(huán)境,面對新的市場環(huán)境,從電氣設(shè)備的運(yùn)維管理入手是電廠降低成本、提高效益的有效途徑。為此,針對電廠電氣設(shè)備故障和檢修的問題進(jìn)行分析研究十分必要。
1 電廠電氣設(shè)備常見故障及原因
1.1 變電設(shè)備故障
變壓器絕緣性能下降、氣體壓力升高。如油浸式變壓器的絕緣油遇到空氣時(shí)很容易吸收空氣中的水分與空氣中的氧氣發(fā)生氧化反應(yīng),在上述理化反應(yīng)的協(xié)同作用下引發(fā)絕緣油劣化,造成絕緣油性能下降,使變壓器線圈的絕緣性能降低。當(dāng)絕緣性能較低時(shí),變壓器線圈局部過熱、局部放電、鐵芯異常,造成變壓器內(nèi)部溫度升高。溫度上升加重了變壓器絕緣油的分解氧化,反應(yīng)產(chǎn)生的氣體滯留溶解在絕緣油中,加重了油質(zhì)劣化。如果上述情況程度較輕,則檢測到的氣體壓力數(shù)值表現(xiàn)出異常,如果程度較重,則會(huì)引發(fā)電路短路,使氣體壓力急劇升高,沖擊壓力繼電器動(dòng)作。
變壓器或發(fā)電機(jī)線圈短路。油浸式變壓器如果發(fā)生線圈短路或者接地的故障,會(huì)在短路部位燒毀線路,嚴(yán)重時(shí)會(huì)引發(fā)變壓器火災(zāi)事故。
此外,停電作業(yè)可能引發(fā)設(shè)備故障。根據(jù)電廠檢修規(guī)定,需要定期對變電站進(jìn)行停電檢修。在平時(shí)很少全停電,工作人員如果在停電時(shí)操作失誤,容易引發(fā)設(shè)備故障。
1.2 供電線路故障
對地短路或者線間短路是引起電氣設(shè)備故障的常見類型。究其原因包括在電氣設(shè)備線路設(shè)計(jì)環(huán)節(jié)對電氣設(shè)備的開關(guān)裝置以及導(dǎo)線容量設(shè)計(jì)不當(dāng),或者電氣設(shè)備施工不符合技術(shù)標(biāo)準(zhǔn)等。
變壓器中性點(diǎn)接地故障。單相三線式變壓器在單相負(fù)載電力供應(yīng)中很常見。通常采用的施工方式是輸出兩個(gè)電壓等級(jí),二次側(cè)中性線接地。這樣可以使變壓器對地電壓較小,而且在遇到高低壓側(cè)混線接觸時(shí)防治低壓側(cè)電壓升高。但是這種方式下一旦出現(xiàn)接地?cái)嗑€,而變壓器仍然供電時(shí)就帶來了很大風(fēng)險(xiǎn)。如果其他電壓相出現(xiàn)對地短路,此時(shí)接地線的接地電阻升高,會(huì)給配電線路、變壓器以及電氣設(shè)備帶來電壓波動(dòng)性風(fēng)險(xiǎn),引發(fā)設(shè)備故障。
地下高壓電纜短路事故。在地下供電項(xiàng)目中,供電線路的優(yōu)點(diǎn)是電纜敷設(shè)場所溫度波動(dòng)性小,也不容易受到外界因素的傷損。但是一旦地下線路出現(xiàn)對地短路或者線間短路的情況,反而給檢修人員增加了困難。尤其是大容量電纜需要備貨運(yùn)到現(xiàn)場才能施工,因此對電廠生產(chǎn)十分不利。
1.3 控制電路及控制設(shè)備故障
斷路器投入失誤。在對電氣設(shè)備檢修完成后,工作人員應(yīng)將斷路器重新投入電源,恢復(fù)電路正常運(yùn)行。電源電路中的動(dòng)力電路應(yīng)在控制電路之前進(jìn)行送電,如果順序顛倒容易存在繼電器或電磁開閉器異常的情況。
線路絕緣故障。正常運(yùn)行的設(shè)備在沒有發(fā)生警報(bào)的情況下出現(xiàn)緊急停車,這樣的故障很可能是線路短路造成的。
電磁接觸器燒毀故障。如果對運(yùn)行中的負(fù)載進(jìn)行頻繁啟停時(shí),可以使用電磁接觸器。由于電磁接觸器規(guī)格型號(hào)選擇不當(dāng),與設(shè)備運(yùn)行負(fù)載的性質(zhì)和需求不匹配,造成電磁接觸器燒毀。在使用過程中,工作人員可通過聽聲音以及觀察外觀的方式判斷電磁接觸器運(yùn)行工況是否正常。通常故障出現(xiàn)的地方是電磁接觸器的主接點(diǎn)??赡芤鸸收系脑虬ōh(huán)境空氣濕度、溫度、粉塵濃度,以及絕緣劣化引起故障電流等因素,多會(huì)引起主接點(diǎn)燒毀。
2 設(shè)備故障處理措施
針對變壓器絕緣性能下降引起的短路情況,可通過設(shè)置雙浮子繼電器來解決。針對變壓器或發(fā)電企線圈短路的情況,可在變壓器內(nèi)部設(shè)置比率差機(jī)動(dòng)繼電保護(hù)等故障保護(hù)裝置,在發(fā)生故障時(shí)將供電電路及時(shí)切斷。對停電作業(yè)引發(fā)的故障,可加強(qiáng)停電檢修作業(yè)標(biāo)準(zhǔn)化管理。在檢修作業(yè)完成后,工作人員必須認(rèn)真檢查設(shè)備接地線是否都連接可靠,采取清單核查制度以及專人檢查制度,檢查停電檢修作業(yè)后是否恢復(fù)到正常情況。
針對供電線路故障中線路設(shè)計(jì)環(huán)節(jié)的問題,應(yīng)從電氣設(shè)計(jì)環(huán)節(jié)和工程施工環(huán)節(jié)進(jìn)行質(zhì)量把控,選擇適當(dāng)?shù)拈_關(guān)裝置和導(dǎo)線容量,并嚴(yán)格按照電氣設(shè)備的施工技術(shù)標(biāo)準(zhǔn)進(jìn)行施工。此外,采取合理的保護(hù)措施,線路保護(hù)裝置類型和保護(hù)裝置參數(shù)設(shè)定應(yīng)相互協(xié)調(diào),提高保護(hù)裝置動(dòng)作合理性,避免事故擴(kuò)大化。對地下高壓電纜事故,可通過在線監(jiān)測的方式及時(shí)發(fā)現(xiàn)地下電纜運(yùn)行工況,加強(qiáng)設(shè)備物資、檢修維護(hù)部門之間的協(xié)作,提高線路檢修時(shí)效性。
針對控制電路或控制設(shè)備引起的故障,應(yīng)先激活控制電路的電源,確保繼電器和電磁開閉器不發(fā)生異常動(dòng)作且沒有警報(bào)后,再將斷路器投入動(dòng)力電源。如果設(shè)備在沒有發(fā)生警報(bào)的情況下出現(xiàn)緊急停車,中央監(jiān)控室通常會(huì)提示停車警報(bào)信息,此時(shí)工作人員需要對可能存在異常區(qū)域部位進(jìn)行一一排查,找到故障原因并進(jìn)行處理。在安裝電磁接觸器時(shí)應(yīng)根據(jù)設(shè)備負(fù)載的性質(zhì)和運(yùn)行特征選擇合適的規(guī)格型號(hào)。檢查電磁接觸器運(yùn)行聲音并觀察外觀是否正常,同時(shí)注意環(huán)境濕度、溫度、粉塵濃度條件,同時(shí)注意絕緣劣化故障電流,避免電磁接觸器主接點(diǎn)燒毀。
3 設(shè)備維護(hù)技術(shù)要點(diǎn)分析
3.1 嚴(yán)格執(zhí)行各種電氣設(shè)備運(yùn)行條件和參數(shù)
電氣設(shè)備運(yùn)行條件和參數(shù)是否與電力生產(chǎn)條件吻合,以及是否滿足電氣設(shè)備性能參數(shù)技術(shù)標(biāo)準(zhǔn)對電氣設(shè)備運(yùn)行和維護(hù)有著密切影響。在電力企業(yè)設(shè)備維護(hù)過程中,首先要確保電氣設(shè)備或供電系統(tǒng)的工作條件和運(yùn)行參數(shù)在允許的合理范圍內(nèi),這樣才能保障設(shè)備使用壽命,降低設(shè)備能耗,降低設(shè)備維護(hù)管理成本。工作人員必須嚴(yán)格按照電氣設(shè)備和供電系統(tǒng)的生產(chǎn)管理規(guī)程進(jìn)行操作,加強(qiáng)對電氣設(shè)備日常運(yùn)行參數(shù)的監(jiān)測和控制,并做好設(shè)備運(yùn)行情況記錄。
3.2 加強(qiáng)電氣設(shè)備日常巡查和定期檢修
電氣設(shè)備日常運(yùn)行中存在風(fēng)險(xiǎn)隱患,一些風(fēng)險(xiǎn)隱患僅僅依靠電氣設(shè)備的電子顯示裝置上是不容易被發(fā)現(xiàn),因此除了在操作過程中做好對電氣設(shè)備運(yùn)行條件和參數(shù)的監(jiān)測控制以外,工作人員還要加強(qiáng)電氣設(shè)備日常巡查和定期檢修。巡查過程中重點(diǎn)對電子儀表不能顯示的一些部位,如充油設(shè)備的油位是否異常、是否存在漏油的現(xiàn)象、開關(guān)設(shè)備的溫度是否異常、母線節(jié)點(diǎn)位置是否存在溫度異常、電纜線路是否磨損進(jìn)行檢查。在電氣設(shè)備的日常巡查工作中,采用列清單的檢修執(zhí)行方式,工作人員在日常巡檢過程中嚴(yán)格對照電氣設(shè)備清單所列的條目和內(nèi)容進(jìn)行檢查,并認(rèn)真填寫好設(shè)備記錄及巡查內(nèi)容,同步錄入到電廠電氣設(shè)備運(yùn)維管理信息系統(tǒng)中。結(jié)合電廠電氣設(shè)備管理的要求,定期根據(jù)電廠生產(chǎn)任務(wù)情況對電氣設(shè)備的日常巡查和定期檢修計(jì)劃和具體方案進(jìn)行完善,制定科學(xué)合理的電氣設(shè)備策略,并根據(jù)設(shè)備檢修的結(jié)果對電氣設(shè)備管理規(guī)程、操作標(biāo)準(zhǔn)和策略進(jìn)一步優(yōu)化。
3.3 提升電氣設(shè)備與供電系統(tǒng)風(fēng)險(xiǎn)排查和維護(hù)技術(shù)水平
建立科學(xué)的電氣設(shè)備風(fēng)險(xiǎn)排查機(jī)制,通過風(fēng)險(xiǎn)辨識(shí)和風(fēng)險(xiǎn)排查,有效防控電氣設(shè)備出現(xiàn)大的故障。推動(dòng)電廠電氣設(shè)備管理信息化建設(shè),將電氣設(shè)備運(yùn)行工況的數(shù)據(jù)信息納入到電氣設(shè)備管理系統(tǒng)中,及時(shí)收集電氣設(shè)備運(yùn)維管理數(shù)據(jù)。利用人工智能技術(shù)和計(jì)算機(jī)技術(shù)加強(qiáng)對電氣設(shè)備運(yùn)行數(shù)據(jù)信息的處理分析能力,提升設(shè)備故障診斷能力,盡早發(fā)現(xiàn)設(shè)備風(fēng)險(xiǎn)隱患,盡早遏制消除風(fēng)險(xiǎn),降低電氣設(shè)備事故發(fā)生率。設(shè)備管理系統(tǒng)中積累越來越多的數(shù)據(jù),工作人員對數(shù)據(jù)進(jìn)行深度分析,挖掘出電氣設(shè)備運(yùn)維信息內(nèi)在關(guān)聯(lián)及演變規(guī)律,幫助設(shè)備管理維護(hù)人員制定和優(yōu)化方案措施,提升電氣設(shè)備維護(hù)水平。
4 設(shè)備檢修技術(shù)要點(diǎn)分析
4.1 采取分級(jí)檢修的管理方式
電廠電氣設(shè)備眾多,提高檢修作業(yè)效率和檢修水平的前提是對電氣設(shè)備進(jìn)行分級(jí)處理,然后采取有針對性的檢修方法以及檢修手段??梢灾苯訉﹄姎庠O(shè)備進(jìn)行分級(jí),然后對不同級(jí)別的電氣設(shè)備進(jìn)行重要性評估,然后根據(jù)不同級(jí)別的電氣設(shè)備進(jìn)行檢修技術(shù)參數(shù)和技術(shù)標(biāo)準(zhǔn)的確定。通過對不同級(jí)別的電氣設(shè)備劃分檢修基準(zhǔn),使電氣設(shè)備檢修更加規(guī)范化,各項(xiàng)技術(shù)參數(shù)更加明確化。在電氣設(shè)備實(shí)際檢修工作中,技術(shù)人員必須根據(jù)電廠電氣設(shè)備檢修作業(yè)的具體規(guī)程和具體標(biāo)準(zhǔn)實(shí)施分級(jí)檢修,提高設(shè)備檢修作業(yè)標(biāo)準(zhǔn)化程度。
4.2 加強(qiáng)設(shè)備檢測技術(shù)水平
設(shè)備檢修的關(guān)鍵是對設(shè)備缺陷或異常情況進(jìn)行分析評價(jià),從而根據(jù)評價(jià)的結(jié)果制定并采取檢修方式方法。電廠電氣設(shè)備檢修與普通電氣設(shè)備檢修具有更復(fù)雜的特點(diǎn)。電氣設(shè)備環(huán)環(huán)相扣,一個(gè)節(jié)點(diǎn)出現(xiàn)問題極容易引發(fā)系統(tǒng)連鎖性反應(yīng)。而及時(shí)有效地切斷故障連鎖鏈條是避免故障蔓延的關(guān)鍵。從設(shè)備檢修技術(shù)入手,采用信息技術(shù)和數(shù)據(jù)技術(shù)作為設(shè)備檢修工作的重要支撐,推動(dòng)電氣設(shè)備向著自動(dòng)化智能化的檢測方向發(fā)展。電氣設(shè)備自動(dòng)監(jiān)測技術(shù)的應(yīng)用實(shí)現(xiàn)了在線檢測和循環(huán)檢測,通過實(shí)時(shí)收集電氣設(shè)備運(yùn)行的參數(shù),與參數(shù)的合理值進(jìn)行對照,自動(dòng)識(shí)別出存在缺陷或異常隱患的設(shè)備,提升設(shè)備檢測的準(zhǔn)確度和時(shí)效性。
4.3 對設(shè)備故障檢修進(jìn)行總結(jié)分析
電氣設(shè)備故障檢修全過程不僅包括對缺陷故障的識(shí)別診斷,以及對設(shè)備異常的解決處理,而且還包括度設(shè)備故障檢修的總結(jié)分析。推動(dòng)電氣設(shè)備檢修信息化智能化發(fā)展,建立電氣設(shè)備運(yùn)行數(shù)據(jù)庫,對電氣設(shè)備故障檢修的信息數(shù)據(jù)進(jìn)行統(tǒng)計(jì)分析,挖掘電力系統(tǒng)中各個(gè)設(shè)備故障隱藏的內(nèi)在關(guān)聯(lián)及風(fēng)險(xiǎn)隱患演變的規(guī)律。對電氣設(shè)備故障和線路故障數(shù)據(jù)分析研究,制定和優(yōu)化電氣設(shè)備故障檢修方案以及電氣設(shè)備運(yùn)行風(fēng)險(xiǎn)防控策略,防止設(shè)備故障擴(kuò)大化,從源頭上降低設(shè)備故障發(fā)生率。
5 結(jié)語
電氣設(shè)備在電廠的生產(chǎn)運(yùn)營過程中有著不容忽視的地位。可以說,只有在電氣設(shè)備運(yùn)行狀況保持良好的狀態(tài)下,才能使電廠生產(chǎn)任務(wù)和管理目標(biāo)得以實(shí)現(xiàn)。近年來,電廠電氣設(shè)備不斷升級(jí),同時(shí)信息技術(shù)、智能技術(shù)在電氣設(shè)備運(yùn)維中的應(yīng)用也越來越多。在新的形勢下,針對電廠電氣設(shè)備常見故障進(jìn)行分析,優(yōu)化設(shè)備故障檢修方案,不僅是提升電廠設(shè)備檢修維護(hù)水平的有效策略,同時(shí)也是推動(dòng)電廠實(shí)現(xiàn)高質(zhì)量管理目標(biāo)的重要保障。
參考文獻(xiàn)
[1] 李金科.試論電氣設(shè)備的運(yùn)行維護(hù)及故障檢修[J].科技風(fēng),2017(20):147-148.
[2] 陳景輝.試論水電站電氣設(shè)備運(yùn)行維護(hù)及故障檢修[J].科技風(fēng),2015(21):88.
[3] 張凱強(qiáng).淺析火力發(fā)電廠發(fā)電機(jī)的檢修與維護(hù)方法[J].科技尚品,2017(4):133.
[4] 張孟庭.對水電站電氣設(shè)備運(yùn)行維護(hù)的幾點(diǎn)探討[J].科技展望,2016(31):97.
[5] 沙海丁·賽德爾丁.水電站電氣設(shè)備運(yùn)行維護(hù)與故障檢修分析[J].內(nèi)蒙古水利,2018(1):79-80.
張舜
[摘? ? 要]電氣設(shè)備是電廠生產(chǎn)運(yùn)營中的重要組成部分,對電廠經(jīng)營效益和安全管理工作目標(biāo)的實(shí)現(xiàn)有著緊密的關(guān)系。通過對電廠電氣設(shè)備常見故障進(jìn)行分析,采取科學(xué)的設(shè)備故障處理措施是十分必要的。本文就這一議題進(jìn)行了探討,并對電氣設(shè)備維護(hù)技術(shù)和檢修技術(shù)的要點(diǎn)進(jìn)行了論述,供相關(guān)人士參考。
[關(guān)鍵詞]電氣設(shè)備故障處理;故障原因;技術(shù)維護(hù);檢修措施
[中圖分類號(hào)]TM621 [文獻(xiàn)標(biāo)志碼]A [文章編號(hào)]2095–6487(2020)09–00–03
[Abstract]Electrical equipment is an important part of power plant production and operation, which has a close relationship with the realization of power plant operation efficiency and safety management objectives. By analyzing the common faults of electrical equipment in power plant, it is very necessary to take scientific measures to deal with equipment faults. This paper discusses this issue, and discusses the key points of electrical equipment maintenance technology and overhaul technology, for reference.
[Keywords]electrical equipment fault treatment; fault reason; technical maintenance; overhaul measures
只有確保電氣設(shè)備始終處于安全穩(wěn)定的運(yùn)行狀態(tài),才能使電廠生產(chǎn)運(yùn)營的目標(biāo)順利實(shí)現(xiàn)。近年來,電力企業(yè)面臨越來越激烈的市場競爭環(huán)境,面對新的市場環(huán)境,從電氣設(shè)備的運(yùn)維管理入手是電廠降低成本、提高效益的有效途徑。為此,針對電廠電氣設(shè)備故障和檢修的問題進(jìn)行分析研究十分必要。
1 電廠電氣設(shè)備常見故障及原因
1.1 變電設(shè)備故障
變壓器絕緣性能下降、氣體壓力升高。如油浸式變壓器的絕緣油遇到空氣時(shí)很容易吸收空氣中的水分與空氣中的氧氣發(fā)生氧化反應(yīng),在上述理化反應(yīng)的協(xié)同作用下引發(fā)絕緣油劣化,造成絕緣油性能下降,使變壓器線圈的絕緣性能降低。當(dāng)絕緣性能較低時(shí),變壓器線圈局部過熱、局部放電、鐵芯異常,造成變壓器內(nèi)部溫度升高。溫度上升加重了變壓器絕緣油的分解氧化,反應(yīng)產(chǎn)生的氣體滯留溶解在絕緣油中,加重了油質(zhì)劣化。如果上述情況程度較輕,則檢測到的氣體壓力數(shù)值表現(xiàn)出異常,如果程度較重,則會(huì)引發(fā)電路短路,使氣體壓力急劇升高,沖擊壓力繼電器動(dòng)作。
變壓器或發(fā)電機(jī)線圈短路。油浸式變壓器如果發(fā)生線圈短路或者接地的故障,會(huì)在短路部位燒毀線路,嚴(yán)重時(shí)會(huì)引發(fā)變壓器火災(zāi)事故。
此外,停電作業(yè)可能引發(fā)設(shè)備故障。根據(jù)電廠檢修規(guī)定,需要定期對變電站進(jìn)行停電檢修。在平時(shí)很少全停電,工作人員如果在停電時(shí)操作失誤,容易引發(fā)設(shè)備故障。
1.2 供電線路故障
對地短路或者線間短路是引起電氣設(shè)備故障的常見類型。究其原因包括在電氣設(shè)備線路設(shè)計(jì)環(huán)節(jié)對電氣設(shè)備的開關(guān)裝置以及導(dǎo)線容量設(shè)計(jì)不當(dāng),或者電氣設(shè)備施工不符合技術(shù)標(biāo)準(zhǔn)等。
變壓器中性點(diǎn)接地故障。單相三線式變壓器在單相負(fù)載電力供應(yīng)中很常見。通常采用的施工方式是輸出兩個(gè)電壓等級(jí),二次側(cè)中性線接地。這樣可以使變壓器對地電壓較小,而且在遇到高低壓側(cè)混線接觸時(shí)防治低壓側(cè)電壓升高。但是這種方式下一旦出現(xiàn)接地?cái)嗑€,而變壓器仍然供電時(shí)就帶來了很大風(fēng)險(xiǎn)。如果其他電壓相出現(xiàn)對地短路,此時(shí)接地線的接地電阻升高,會(huì)給配電線路、變壓器以及電氣設(shè)備帶來電壓波動(dòng)性風(fēng)險(xiǎn),引發(fā)設(shè)備故障。
地下高壓電纜短路事故。在地下供電項(xiàng)目中,供電線路的優(yōu)點(diǎn)是電纜敷設(shè)場所溫度波動(dòng)性小,也不容易受到外界因素的傷損。但是一旦地下線路出現(xiàn)對地短路或者線間短路的情況,反而給檢修人員增加了困難。尤其是大容量電纜需要備貨運(yùn)到現(xiàn)場才能施工,因此對電廠生產(chǎn)十分不利。
1.3 控制電路及控制設(shè)備故障
斷路器投入失誤。在對電氣設(shè)備檢修完成后,工作人員應(yīng)將斷路器重新投入電源,恢復(fù)電路正常運(yùn)行。電源電路中的動(dòng)力電路應(yīng)在控制電路之前進(jìn)行送電,如果順序顛倒容易存在繼電器或電磁開閉器異常的情況。
線路絕緣故障。正常運(yùn)行的設(shè)備在沒有發(fā)生警報(bào)的情況下出現(xiàn)緊急停車,這樣的故障很可能是線路短路造成的。
電磁接觸器燒毀故障。如果對運(yùn)行中的負(fù)載進(jìn)行頻繁啟停時(shí),可以使用電磁接觸器。由于電磁接觸器規(guī)格型號(hào)選擇不當(dāng),與設(shè)備運(yùn)行負(fù)載的性質(zhì)和需求不匹配,造成電磁接觸器燒毀。在使用過程中,工作人員可通過聽聲音以及觀察外觀的方式判斷電磁接觸器運(yùn)行工況是否正常。通常故障出現(xiàn)的地方是電磁接觸器的主接點(diǎn)。可能引起故障的原因包括環(huán)境空氣濕度、溫度、粉塵濃度,以及絕緣劣化引起故障電流等因素,多會(huì)引起主接點(diǎn)燒毀。
2 設(shè)備故障處理措施
針對變壓器絕緣性能下降引起的短路情況,可通過設(shè)置雙浮子繼電器來解決。針對變壓器或發(fā)電企線圈短路的情況,可在變壓器內(nèi)部設(shè)置比率差機(jī)動(dòng)繼電保護(hù)等故障保護(hù)裝置,在發(fā)生故障時(shí)將供電電路及時(shí)切斷。對停電作業(yè)引發(fā)的故障,可加強(qiáng)停電檢修作業(yè)標(biāo)準(zhǔn)化管理。在檢修作業(yè)完成后,工作人員必須認(rèn)真檢查設(shè)備接地線是否都連接可靠,采取清單核查制度以及專人檢查制度,檢查停電檢修作業(yè)后是否恢復(fù)到正常情況。
針對供電線路故障中線路設(shè)計(jì)環(huán)節(jié)的問題,應(yīng)從電氣設(shè)計(jì)環(huán)節(jié)和工程施工環(huán)節(jié)進(jìn)行質(zhì)量把控,選擇適當(dāng)?shù)拈_關(guān)裝置和導(dǎo)線容量,并嚴(yán)格按照電氣設(shè)備的施工技術(shù)標(biāo)準(zhǔn)進(jìn)行施工。此外,采取合理的保護(hù)措施,線路保護(hù)裝置類型和保護(hù)裝置參數(shù)設(shè)定應(yīng)相互協(xié)調(diào),提高保護(hù)裝置動(dòng)作合理性,避免事故擴(kuò)大化。對地下高壓電纜事故,可通過在線監(jiān)測的方式及時(shí)發(fā)現(xiàn)地下電纜運(yùn)行工況,加強(qiáng)設(shè)備物資、檢修維護(hù)部門之間的協(xié)作,提高線路檢修時(shí)效性。
針對控制電路或控制設(shè)備引起的故障,應(yīng)先激活控制電路的電源,確保繼電器和電磁開閉器不發(fā)生異常動(dòng)作且沒有警報(bào)后,再將斷路器投入動(dòng)力電源。如果設(shè)備在沒有發(fā)生警報(bào)的情況下出現(xiàn)緊急停車,中央監(jiān)控室通常會(huì)提示停車警報(bào)信息,此時(shí)工作人員需要對可能存在異常區(qū)域部位進(jìn)行一一排查,找到故障原因并進(jìn)行處理。在安裝電磁接觸器時(shí)應(yīng)根據(jù)設(shè)備負(fù)載的性質(zhì)和運(yùn)行特征選擇合適的規(guī)格型號(hào)。檢查電磁接觸器運(yùn)行聲音并觀察外觀是否正常,同時(shí)注意環(huán)境濕度、溫度、粉塵濃度條件,同時(shí)注意絕緣劣化故障電流,避免電磁接觸器主接點(diǎn)燒毀。
3 設(shè)備維護(hù)技術(shù)要點(diǎn)分析
3.1 嚴(yán)格執(zhí)行各種電氣設(shè)備運(yùn)行條件和參數(shù)
電氣設(shè)備運(yùn)行條件和參數(shù)是否與電力生產(chǎn)條件吻合,以及是否滿足電氣設(shè)備性能參數(shù)技術(shù)標(biāo)準(zhǔn)對電氣設(shè)備運(yùn)行和維護(hù)有著密切影響。在電力企業(yè)設(shè)備維護(hù)過程中,首先要確保電氣設(shè)備或供電系統(tǒng)的工作條件和運(yùn)行參數(shù)在允許的合理范圍內(nèi),這樣才能保障設(shè)備使用壽命,降低設(shè)備能耗,降低設(shè)備維護(hù)管理成本。工作人員必須嚴(yán)格按照電氣設(shè)備和供電系統(tǒng)的生產(chǎn)管理規(guī)程進(jìn)行操作,加強(qiáng)對電氣設(shè)備日常運(yùn)行參數(shù)的監(jiān)測和控制,并做好設(shè)備運(yùn)行情況記錄。
3.2 加強(qiáng)電氣設(shè)備日常巡查和定期檢修
電氣設(shè)備日常運(yùn)行中存在風(fēng)險(xiǎn)隱患,一些風(fēng)險(xiǎn)隱患僅僅依靠電氣設(shè)備的電子顯示裝置上是不容易被發(fā)現(xiàn),因此除了在操作過程中做好對電氣設(shè)備運(yùn)行條件和參數(shù)的監(jiān)測控制以外,工作人員還要加強(qiáng)電氣設(shè)備日常巡查和定期檢修。巡查過程中重點(diǎn)對電子儀表不能顯示的一些部位,如充油設(shè)備的油位是否異常、是否存在漏油的現(xiàn)象、開關(guān)設(shè)備的溫度是否異常、母線節(jié)點(diǎn)位置是否存在溫度異常、電纜線路是否磨損進(jìn)行檢查。在電氣設(shè)備的日常巡查工作中,采用列清單的檢修執(zhí)行方式,工作人員在日常巡檢過程中嚴(yán)格對照電氣設(shè)備清單所列的條目和內(nèi)容進(jìn)行檢查,并認(rèn)真填寫好設(shè)備記錄及巡查內(nèi)容,同步錄入到電廠電氣設(shè)備運(yùn)維管理信息系統(tǒng)中。結(jié)合電廠電氣設(shè)備管理的要求,定期根據(jù)電廠生產(chǎn)任務(wù)情況對電氣設(shè)備的日常巡查和定期檢修計(jì)劃和具體方案進(jìn)行完善,制定科學(xué)合理的電氣設(shè)備策略,并根據(jù)設(shè)備檢修的結(jié)果對電氣設(shè)備管理規(guī)程、操作標(biāo)準(zhǔn)和策略進(jìn)一步優(yōu)化。
3.3 提升電氣設(shè)備與供電系統(tǒng)風(fēng)險(xiǎn)排查和維護(hù)技術(shù)水平
建立科學(xué)的電氣設(shè)備風(fēng)險(xiǎn)排查機(jī)制,通過風(fēng)險(xiǎn)辨識(shí)和風(fēng)險(xiǎn)排查,有效防控電氣設(shè)備出現(xiàn)大的故障。推動(dòng)電廠電氣設(shè)備管理信息化建設(shè),將電氣設(shè)備運(yùn)行工況的數(shù)據(jù)信息納入到電氣設(shè)備管理系統(tǒng)中,及時(shí)收集電氣設(shè)備運(yùn)維管理數(shù)據(jù)。利用人工智能技術(shù)和計(jì)算機(jī)技術(shù)加強(qiáng)對電氣設(shè)備運(yùn)行數(shù)據(jù)信息的處理分析能力,提升設(shè)備故障診斷能力,盡早發(fā)現(xiàn)設(shè)備風(fēng)險(xiǎn)隱患,盡早遏制消除風(fēng)險(xiǎn),降低電氣設(shè)備事故發(fā)生率。設(shè)備管理系統(tǒng)中積累越來越多的數(shù)據(jù),工作人員對數(shù)據(jù)進(jìn)行深度分析,挖掘出電氣設(shè)備運(yùn)維信息內(nèi)在關(guān)聯(lián)及演變規(guī)律,幫助設(shè)備管理維護(hù)人員制定和優(yōu)化方案措施,提升電氣設(shè)備維護(hù)水平。
4 設(shè)備檢修技術(shù)要點(diǎn)分析
4.1 采取分級(jí)檢修的管理方式
電廠電氣設(shè)備眾多,提高檢修作業(yè)效率和檢修水平的前提是對電氣設(shè)備進(jìn)行分級(jí)處理,然后采取有針對性的檢修方法以及檢修手段??梢灾苯訉﹄姎庠O(shè)備進(jìn)行分級(jí),然后對不同級(jí)別的電氣設(shè)備進(jìn)行重要性評估,然后根據(jù)不同級(jí)別的電氣設(shè)備進(jìn)行檢修技術(shù)參數(shù)和技術(shù)標(biāo)準(zhǔn)的確定。通過對不同級(jí)別的電氣設(shè)備劃分檢修基準(zhǔn),使電氣設(shè)備檢修更加規(guī)范化,各項(xiàng)技術(shù)參數(shù)更加明確化。在電氣設(shè)備實(shí)際檢修工作中,技術(shù)人員必須根據(jù)電廠電氣設(shè)備檢修作業(yè)的具體規(guī)程和具體標(biāo)準(zhǔn)實(shí)施分級(jí)檢修,提高設(shè)備檢修作業(yè)標(biāo)準(zhǔn)化程度。
4.2 加強(qiáng)設(shè)備檢測技術(shù)水平
設(shè)備檢修的關(guān)鍵是對設(shè)備缺陷或異常情況進(jìn)行分析評價(jià),從而根據(jù)評價(jià)的結(jié)果制定并采取檢修方式方法。電廠電氣設(shè)備檢修與普通電氣設(shè)備檢修具有更復(fù)雜的特點(diǎn)。電氣設(shè)備環(huán)環(huán)相扣,一個(gè)節(jié)點(diǎn)出現(xiàn)問題極容易引發(fā)系統(tǒng)連鎖性反應(yīng)。而及時(shí)有效地切斷故障連鎖鏈條是避免故障蔓延的關(guān)鍵。從設(shè)備檢修技術(shù)入手,采用信息技術(shù)和數(shù)據(jù)技術(shù)作為設(shè)備檢修工作的重要支撐,推動(dòng)電氣設(shè)備向著自動(dòng)化智能化的檢測方向發(fā)展。電氣設(shè)備自動(dòng)監(jiān)測技術(shù)的應(yīng)用實(shí)現(xiàn)了在線檢測和循環(huán)檢測,通過實(shí)時(shí)收集電氣設(shè)備運(yùn)行的參數(shù),與參數(shù)的合理值進(jìn)行對照,自動(dòng)識(shí)別出存在缺陷或異常隱患的設(shè)備,提升設(shè)備檢測的準(zhǔn)確度和時(shí)效性。
4.3 對設(shè)備故障檢修進(jìn)行總結(jié)分析
電氣設(shè)備故障檢修全過程不僅包括對缺陷故障的識(shí)別診斷,以及對設(shè)備異常的解決處理,而且還包括度設(shè)備故障檢修的總結(jié)分析。推動(dòng)電氣設(shè)備檢修信息化智能化發(fā)展,建立電氣設(shè)備運(yùn)行數(shù)據(jù)庫,對電氣設(shè)備故障檢修的信息數(shù)據(jù)進(jìn)行統(tǒng)計(jì)分析,挖掘電力系統(tǒng)中各個(gè)設(shè)備故障隱藏的內(nèi)在關(guān)聯(lián)及風(fēng)險(xiǎn)隱患演變的規(guī)律。對電氣設(shè)備故障和線路故障數(shù)據(jù)分析研究,制定和優(yōu)化電氣設(shè)備故障檢修方案以及電氣設(shè)備運(yùn)行風(fēng)險(xiǎn)防控策略,防止設(shè)備故障擴(kuò)大化,從源頭上降低設(shè)備故障發(fā)生率。
5 結(jié)語
電氣設(shè)備在電廠的生產(chǎn)運(yùn)營過程中有著不容忽視的地位??梢哉f,只有在電氣設(shè)備運(yùn)行狀況保持良好的狀態(tài)下,才能使電廠生產(chǎn)任務(wù)和管理目標(biāo)得以實(shí)現(xiàn)。近年來,電廠電氣設(shè)備不斷升級(jí),同時(shí)信息技術(shù)、智能技術(shù)在電氣設(shè)備運(yùn)維中的應(yīng)用也越來越多。在新的形勢下,針對電廠電氣設(shè)備常見故障進(jìn)行分析,優(yōu)化設(shè)備故障檢修方案,不僅是提升電廠設(shè)備檢修維護(hù)水平的有效策略,同時(shí)也是推動(dòng)電廠實(shí)現(xiàn)高質(zhì)量管理目標(biāo)的重要保障。
參考文獻(xiàn)
[1] 李金科.試論電氣設(shè)備的運(yùn)行維護(hù)及故障檢修[J].科技風(fēng),2017(20):147-148.
[2] 陳景輝.試論水電站電氣設(shè)備運(yùn)行維護(hù)及故障檢修[J].科技風(fēng),2015(21):88.
[3] 張凱強(qiáng).淺析火力發(fā)電廠發(fā)電機(jī)的檢修與維護(hù)方法[J].科技尚品,2017(4):133.
[4] 張孟庭.對水電站電氣設(shè)備運(yùn)行維護(hù)的幾點(diǎn)探討[J].科技展望,2016(31):97.
[5] 沙海丁·賽德爾丁.水電站電氣設(shè)備運(yùn)行維護(hù)與故障檢修分析[J].內(nèi)蒙古水利,2018(1):79-80.